Ready to order
Ready-made sub-distribution boards
Preconfigured enclosures for common home sizes. Pick a brand and send the whole parts list to your cart, no planning needed.
Order pre-set with: Hager · ABB · Schneider
The ready-made configurations are examples that show what the planner can do. We give no warranty that they are correct, complete or functional. They are not designed for any specific installation. A qualified electrician must check every configuration and adapt it to the installation before it is fitted. Terms of use & safety
63A B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA 2 × 12 TE kompakt
- 2 rows
- 24 TE
Same 2 × 12 TE footprint, but every final circuit gets its own compact 1TE FI/LS: twice the individually protected circuits in the same space.
40A B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA 2 × 12 TE kompakt + Phönix
- 2 rows
- 24 TE
The compact 1TE FI/LS board, plus a Phoenix Contact PE/L/N terminal on every circuit: a real disconnect and test point before each breaker.
63A T2+T3 A 40A 30mA B16 B16 B16 B16 B16 B16 B16 B16 A 40A 30mA B16 B16 B16 B16 B16 B16 B16 B16 40A T2+T3 A 40A 30mA B16 B16 B16 B16 B16 B16 B16 B16 A 40A 30mA B16 B16 B16 B16 B20 B20 B16 B16 40A 40A FIELD 1 A 40A 30mA B16 B16 B16 B16 B16 B16 B16 F 40A 30mA B16 B16 B16 A 40A 30mA B16 FIELD 2 40A T2+T3 A 40A 30mA B16 B16 B16 B16 B16 B16 B16 B16 B16 2 × 3 × 12 TE
- 6 rows
- 72 TE
- 2 fields
Two fields, three rows each. Room for the main house plus an annexe or granny flat.
FIELD 1 63A T2+T3 PE A 63A 30mA B16 B16 B10 B16 B16 N F 63A 30mA B16 B16 B16 B16 B16 B16 B16 N B 40A 30mA B16 N FIELD 2 B16 A 30mA B16 A 30mA B16 A 30mA B16 A 30mA A 63A 30mA B10 B16 B16 B16 B10 B16 B16 N B16 AFDD B16 AFDD B16 AFDD B16 AFDD B16 AFDD B10 AFDD 2 × 4 × 12 TE
- 8 rows
- 96 TE
- 2 fields
A detached house with basement, ground and upper floor: a room plan with 113 sockets and 30 circuits, plus the wired board with arc fault detection and a type B RCD for the EV charger.
Need something else?
Build your own in the planner